Low Voltage Distribution Switchgear with Enhanced Safety Features

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
ODM Services
The supplier provides ODM services
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (20)
  • Low Voltage Distribution Switchgear with Enhanced Safety Features
  • Low Voltage Distribution Switchgear with Enhanced Safety Features
  • Low Voltage Distribution Switchgear with Enhanced Safety Features
  • Low Voltage Distribution Switchgear with Enhanced Safety Features
  • Low Voltage Distribution Switchgear with Enhanced Safety Features
  • Low Voltage Distribution Switchgear with Enhanced Safety Features
Find Similar Products
  • Overview
  • Product Description
  • Use Environment
  • Customizable products
  • About Us
  • Ordering Instructions
Overview

Basic Info.

Model NO.
NCGKYN01
Voltage Level
High Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Output Frequency
50Hz
Operating Voltage
380V
Operating Current
5000A
Use Environment
-15ºC-50ºC
Warranty
24 Months
Transport Package
Standard Export Wooden Box with Pallet
Specification
2625mm*1400mm*2855mm
Trademark
Newcom
Origin
Fujian, China
HS Code
8504409999
Production Capacity
2000pieces/Month

Product Description

Product Description

Low Voltage Distribution Switchgear with Enhanced Safety Features
Use Environment

1. To ensure the peak performance of the Reliable Distribution Switchgear enhanced with superior insulation for safety, it is critical that the ambient air temperature remains within a range no greater than +40°C and no less than -5°C. Furthermore, maintaining an average temperature below +35°C over a 24-hour period is essential for optimal functionality, ensuring longevity and consistent performance.

2. Crafted for flawless indoor installation, this product is meticulously optimized for locales where the altitude does not exceed 2000 meters above sea level. This ensures unwavering performance and exceptional reliability, even in elevated regions.

3. It is ideal for the surrounding air's relative humidity to remain at or below 50% at the maximum temperature of +40°C. Notably, at reduced temperatures, higher relative humidity levels, such as 90% at +20°C, are acceptable, while being mindful of potential condensation issues due to temperature variations.

4. During installation, ensure that the inclination is carefully managed, keeping the equipment within a 5% deviation from the vertical plane, thereby preserving its operational integrity and performance standards.

5. The installation location should be free from intense vibrations and impacts, offering a stable environment that safeguards the electrical components against possible corrosion and ensures a prolonged lifespan.

6. Users with specific requirements are encouraged to engage in discussions with the manufacturer to establish a tailored solution that aligns perfectly with their distinct needs, ensuring complete satisfaction and optimal functionality.

Customizable products
Low Voltage Distribution Switchgear with Enhanced Safety Features

About Us

Low Voltage Distribution Switchgear with Enhanced Safety Features
Ordering Instructions

When placing an order, the User shall provide:

1. A comprehensive diagram of the main circuit distribution system phase layout is required, along with the rated working voltage, rated working current, protection device current settings, and any other essential technical parameters. This ensures custom-tailored manufacturing and optimal system setup, meeting your precise operational needs.

2. Clearly articulate the specifications for both incoming and outgoing cables to guarantee precision in connectivity and maximum efficiency.

3. Provide the model, specification, and quantity details of all main electrical components within the differential cabinet. This facilitates precise customization to suit your distinctive operational requirements.

4. Should bus extrusion or ductwork be necessary between switch cabinets or incoming cabinets, it is crucial to provide exact data such as span and height from the ground to ensure flawless alignment and installation.

5. If the switch cabinet is to be used in special environmental conditions, these should be clearly detailed during the ordering process to ensure it is both suitable and resilient for those conditions.

6. Specify the desired surface color of the switch cabinet, alongside any other particular requests, to ensure the finished product aligns with your aesthetic and functional expectations.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now