High Quality Switchgear Insulation for Enhanced Electrical Safety

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Steel Plate
Manufacturer/Factory & Trading Company
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
OEM Services
The supplier provides OEM services for popular brands
ODM Services
The supplier provides ODM services
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (20)
  • High Quality Switchgear Insulation for Enhanced Electrical Safety
  • High Quality Switchgear Insulation for Enhanced Electrical Safety
  • High Quality Switchgear Insulation for Enhanced Electrical Safety
  • High Quality Switchgear Insulation for Enhanced Electrical Safety
  • High Quality Switchgear Insulation for Enhanced Electrical Safety
  • High Quality Switchgear Insulation for Enhanced Electrical Safety
Find Similar Products
  • Overview
  • Product Description
  • Use Environment
  • Customizable products
  • About Us
  • Ordering Instructions
Overview

Basic Info.

Model NO.
NCGKYN01
Voltage Level
High Voltage
Installation
Fixed
Structure
Cabinet
Current
AC
Output Frequency
50Hz
Operating Voltage
380V
Operating Current
5000A
Use Environment
-15ºC-50ºC
Warranty
24 Months
Transport Package
Standard Export Wooden Box with Pallet
Specification
2625mm*1400mm*2855mm
Trademark
Newcom
Origin
Fujian, China
HS Code
8504409999
Production Capacity
2000pieces/Month

Product Description

Product Description

High Quality Switchgear Insulation for Enhanced Electrical Safety
Use Environment

1. To ensure peak efficiency and superior performance of the Reliable Distribution Switchgear equipped with Enhanced Insulation for Safety, it is essential that the ambient air temperature remains within the confines of +40°C at the maximum, and does not drop below -5°C. Moreover, to guarantee uninterrupted functionality, the rolling average temperature over any 24-hour cycle must be maintained below +35°C.

2. Engineered for flawless indoor installation, this exceptional product is tailored for environments where the altitude does not exceed 2000 meters above sea level. This specification is critical to ensuring its steadfast functionality and unwavering reliability.

3. For optimum performance, the relative humidity of the surrounding air should preferably be capped at 50% when the temperature peaks at +40°C. However, at cooler temperatures, higher relative humidity levels are acceptable, such as 90% at +20°C, provided that potential condensation caused by temperature variances is taken into account.

4. During setup, it is imperative to pay meticulous attention to the equipment's inclination, ensuring it remains within a 5% deviation from a vertical alignment to safeguard its operational integrity.

5. The designated installation site must be devoid of significant vibrations and impacts, offering a stable setting that shields the electrical components from any potential corrosion, thus extending their longevity and performance.

6. For users with distinctive requirements, we highly recommend engaging in discussions with the manufacturer. This proactive approach will facilitate the development of a custom solution precisely tailored to your specific needs, ensuring unparalleled satisfaction.

Customizable products
High Quality Switchgear Insulation for Enhanced Electrical Safety

About Us

High Quality Switchgear Insulation for Enhanced Electrical Safety
Ordering Instructions

When placing an order, the User shall provide:

1. A comprehensive diagram detailing the main circuit distribution system phase layout, including the rated working voltage, rated working current, protection device current settings, and any additional necessary technical parameters. This information is crucial to ensure accurate, made-to-measure manufacturing and optimal setup.

2. Clearly articulate the specifications for both incoming and outgoing cables. Precision in these details is pivotal to achieving flawless connectivity and maximizing efficiency.

3. Furnish the model, specification, and quantity details of all primary electrical components housed within the differential cabinet. This will enable precise customization to meet your specific operational demands.

4. If integration of bus extrusion or ductwork is required between switch cabinets or incoming cabinets, provide exact data such as span and height from the ground. This ensures impeccable alignment and installation.

5. In cases where the switch cabinet will operate under special environmental conditions, these should be thoroughly described during the ordering process. This ensures the product's suitability and durability in such settings.

6. Specify the preferred surface color for the switch cabinet along with any other particular requirements. This guarantees that the final product aligns with both your aesthetic preferences and functional expectations.